2. Enter the digits for the password by pressing the and buttons.
Press the to move to the next digit. Press to move back.
If the wrong password is entered the display will flash NO for 5 seconds
then return to normal.
3. Press and when the correct password is displayed.
The buttons will be unlocked.
Once the security has been disabled, a password needs to be re-created to
protect the settings.
Thermostat Specifications
Operating Voltage 18-30 VAC
Maximum Load Current 1 Amp Max per Output Terminal
4 Amp Total Load
Output Type Latching Relays
Batteries 2 AA Alkaline in Series
Battery Life 2 Years Typical
Ambient Operating Temperature 14°F (-10°C) to 122°F (60°C)
Storage Temperature -4°F (-20°C) to 140°F (60°C)
Troubleshooting
If problems with thermostat cannot be resolved, contact:
www.invensyscontrols.com
or
Technical Support: (800) 445-8299
Monday-Friday 7:30 AM - 5:30 PM CST
13
Problem Action
Thermostat does not turn on system.
Check wiring
(see Wiring Diagrams section).
System turns on too often.
Increase temperature differential
(see Pop-Up Wizard section).
System fan does not operate
properly.
Move fan option switch to either gas
or electric, to match system (see
System Switch Selection section).
Thermostat does not display
proper room temperature.
Check F/C (Fahrenheit/Celsius)
setting (see Pop-Up Wizard section).
Display shows HI or LO and room
temperature is normal.
Call a licensed service person to
replace/repair.