THERMOSTATS
Robertshaw
®
proprietary and confidential ©2014 1
Vista de página 0
1 2 3 4 5 6 ... 95 96

Resumo do Conteúdo

Página 1 - THERMOSTATS

THERMOSTATS Robertshaw® proprietary and confidential ©2014 1

Página 2

– Conventional Heat Pump • No control at air handler • Thermostat controlled – Gas Furnace • Plenum switch • Electronic furnace control • Furnace c

Página 3 -  Residual Fan

 Typical fan selections are:  On  Auto  Intermittent  On provides 24 / 7 continuous fan activated  Auto provides fan when air handler is on in h

Página 4 -  G = Fan

• Advantages of Intermittent Fan • Improve comfort with constant moving air • Less cost due to less compressor run time • For example, on 10 minute

Página 5 - – Blower motor

Residual Fan – Applied to forced air systems only – Allows fan to run after a call for either heating or cooling • Pulls built up HVAC heat or cool in

Página 6

 Continuous Fan is minimal kWh usage  Energy saving on Furnace Blower is worth monetary savings  Opportunities to Save Energy:  Zoning  Indoor Ai

Página 7 -  Not needed by some systems

 Staging is a control feature where a higher or lower power consumption level of heating or cooling is enabled  Staging can be automatic or manual 

Página 8 -  Inside

 Humidity adds moisture to the air during a heat call  Dry air can cause dry skin and discomfort  Adding humidity makes the air more comfortable 

Página 9 -  Living Room

 Differential is the difference between the set point and the maximum allowed deviation from set point before the system calls for Heating or Cooling

Página 10 - – MilliVolt

 Balance Point control is used to turn OFF inefficient equipment and turn ON more efficient equipment

Página 11 -  Intermittent

• Enthalpy - Total amount of heat in one pound of substance calculated from accepted temperature base, expressed in BTUs per pound mass • Enthalpy of

Página 13 - Residual Fan

Enthalpy Changeover Setpoint The A,B,C,D enthalpy setpoints adjust enthalpy changeover characteristics. The “A” setting provides the greatest energy

Página 14 -  Indoor Air Quality

•MECHANICAL •ELECTRONIC © Invensys 2012 Invensys proprietary & confidential

Página 15

Mechanical Thermostats – Bi-metal thermometer • Strip of two different metals (iron and copper) • Each metal has a different response to temperature •

Página 16

Digital Non-Programmable – Equivalent to mechanical thermostat – Solid-state operation • No mechanical wear • Elimination of expensive metals – Can co

Página 17

Digital Programmable – Adds ON/OFF schedules – Reduces energy use when comfort is not critical – Normally 4 periods per day • Morning • Day • Evenin

Página 18

– Offers ability to sense temperature in locations away from thermostat • Outside • Other indoor spaces (such as bedroom) – Sensors can be used for in

Página 19

•RF •ZIGBEE® •WI-FI •RUBEE® © Invensys 2012 Invensys proprietary & confidential

Página 20

• Improves ease of retrofit • Adds flexibility • Reduces cost of multiple zone management • Enables remote support

Página 21 - •ELECTRONIC

Pros • Long Distance • Industry History Cons • Higher frequencies require higher power consumption • Interference concerns

Página 22 - – Bi-metal thermometer

Pros • Self discovering • Long distance • Mesh Network Cons • Power requirements high • Infrastructure can be costly Mesh Network

Página 23 - Digital Non-Programmable

 Short Cycle Delay  Remote Sensors  Time of Day Zoning  Residual Fan  Intermittent Fan  Staging  Humidity Controls  Differentials  Balance Po

Página 24 -

1. Devices join utility network 2. Demand Response events • Consumer can opt ‘in’ or ‘out’ 3. Load Control events 4. Pricing messages • Unsecured to

Página 25 - • Outside

Pros • Cost • Industry Standard • Internet Connectivity Cons • Security • Interference Concerns

Página 26 - © Invensys 2012

Pros • Less interference • Less power • Packet based • IEEE 1902.1 Cons • Limited distance • Slower communication speed

Página 27 - • Enables remote support

Internet Thermostat Controller web page for PC/Mac and smartphone At-a-glance energy usage on iPhone Internet hub to wireless gateway Integration wi

Página 28

• Advanced systems monitor power usage by circuit • Creates energy profiles • Can help identify problem appliances and sources early Heat Pump Refrige

Página 29 - Mesh Network

• Wall Units • Internet • Smart Phone © Invensys 2012

Página 30 - 3. Load Control events

Technology – Open protocols (ZigBee®, Wi-Fi, etc.) – Smart-grid integrated controls – Adaptive predictive controls algorithms – Touch-screen interacti

Página 31

• Ability to monitor remotely • Ability to control remotely

Página 33 - Internet

•MONITORING •TARIFF / RATE FLEXIBILITY •CONTROL © Invensys 2012 Invensys proprietary & confidential

Página 34 - • Creates energy profiles

 W1 = 1st stage Heating  W2 = 2nd Stage Heating  E = Emergency Heating  Aux = Auxiliary Heating  Y = Heat pump Heating  G

Página 35 - • Smart Phone

• Simplify meter reading • Enhance data collection efficiency • Reduce manpower costs

Página 36

• Differences in rates based on usage and time of day • Rate flexibility depends on total usage • Rate incentives for utility control of energy usage

Página 37

• Complete energy control by utility or municipality • Better distribution of energy resources • More reliable supply overall

Página 38

• From creators of Apple’s iPod - next generation thermostats

Página 39 - •CONTROL

• Launched in 1990 by U.S. EPA • Originally targeted power plants in attempt to lower energy consumption and greenhouse gas emissions • Expanded to la

Página 40 - • Simplify meter reading

• New designation to identify products that contribute to energy conservation • Replacement term for products previously labeled Energy Star • Identif

Página 42

Robertshaw® i2 Deluxe Series • Setup Wizard in multi-languages (English, Spanish and French) • Humidity Control • Independent remote and outdoor senso

Página 43

WALL THERMOSTAT

Página 44

Contractor ID Feature Set your name and phone number in the display to remind customers to call you for service. Conversational Menus Take the progra

Página 45

• Cooling Air Conditioning System Components – Condenser – Evaporator – Compressor – TXV – Blower motor – Heater – Receiver – Drier – Fan

Página 46

9801i2  1 Heat / 1 Cool  Menu Driven Display  Set-up Wizard  Humidity Control  Temperature override  10 minutes to 365 days 9825i2  Same as a

Página 48 - WALL THERMOSTAT

• Robertshaw RS 2000/3000 Economy Series • Adjustable Temperature Differential • Worry-Free Memory Retention • Low Temperature Freeze Protection • Fil

Página 49

Note the Light symbol. Differentiates RS3110 cover from other Economy series

Página 50 -  Humidity Control

• Bigger, Brighter Display with blue backlight • Adjustable Temperature Differential • Automatic Compressor Short Cycle Protection • Separate “O” and

Página 52

• Pop-up Wizard • Engineered True Blue backlight display • Largest Temperature Display Character Size • Soft Touch Keys • Set-up Test Mode • Auto Chan

Página 54

i2 Series

Página 55

RS456 Series

Página 56 - • Easy Change Battery Access

 Anticipation – the activation or deactivation in advance of ambient temperature reaching set point  Energy Efficient Recovery – thermostat to initi

Página 57

RS2000 Series RS3000 Series

Página 58

Competitive Comparison Robertshaw® Honeywell White Rodgers Family Model or SKU 97xxi2 & 98xxi2 TH8000 1F90 Series Menu-driven operation Ye

Página 59

Pros and Cons Invensys Controls Competition Menu-driven operation Dot Matrix Display allows for common language programming, ease of use & insta

Página 60 - RS2000 Series RS3000 Series

Value Proposition Wholesaler / Distributor Contractor End-User Menu-driven operation Easier to sell Easy Installation Easier to Understand and use

Página 61 - Competitive

Features Robertshaw® Honeywell White-Rogers Braeburn Family Model or SKU RS4000/RS5000 RS6000 TH5000 TH6000 1F80 series 3000/5000 Auto Changeove

Página 62 - More energy costs

Pros and Cons Invensys Controls Competition Auto Changeover Better comfort in Spring and Fall More trips to the stat Pop-Up Wizard Programming Sim

Página 63 - Contractor End-User

Value Proposition Wholesaler / Distributor Contractor End-User Auto Changeover Less SKU’s on shelf Less programming Greater Comfort Pop-Up Wizard Pr

Página 64 - Yes Yes Yes Yes

Competitive Comparison Robertshaw® Honeywell White/ Rodgers Braeburn Family Model or SKU RS2000 / RS3000 TH1000 / TH2000 TH3000 / TH4000 1F70 ser

Página 65 - Requires separate

Pro’s and Con’s Invensys Controls Competition Larger Display & Characters Easier to See and Read Smaller Characters Filter Monitor Convenient R

Página 66

Value Proposition Wholesaler / Distributor Contractor End-User Larger Display & Characters Easier to Sell Easier to read & Set-up Easier to r

Página 67 - Yes No No No

 Protection of compressor to reduce excessive cycling  Adjustable 0 to 5 minute short cycle delay  Usually 1 minute increments  Applied after call

Página 69 - Proposition

Displayed Choice Default SCAL F° or C° F° CLOC 12 or 24 hour 12 LITE 1=always on, 0=off 0 DIFF Set Differential, 0.5-3 F° or 0.5-1.5 C°

Página 70

• Press Fan and HEAT/COOL buttons together for 10 seconds Press at same time

Página 71

• Press FAN and HEAT/COOL buttons for 10 seconds • Press the HEAT/COOL button to turn on heat. A second press will turn on 2nd stage of heat • Contin

Página 72 - Press at same time

• Press the UP and DOWN buttons simultaneously for 3 seconds • Pop-Up Menu will initiate

Página 73 - • To exit the test mode for:

• Press DOWN and HEAT/COOL buttons simultaneously – Hold for 10 seconds • A lock will appear in the – Upper left hand corner of the RS4000 series –

Página 74 - • Pop-Up Menu will initiate

– C: 24 VAC Common – R: 24 VAC – Y1: 1st stage cooling – E/W1: Emergency heat / 1st stage heating – W2: 2nd stage heating – Y2: 2nd stage cooling – L:

Página 76 - – G: Fan

Power may be provided by either (Dual Power) • 24 VAC • 2 (AA) Batteries • Thermostats with batteries and powered by 24V AC will continue to functio

Página 77

• There is NO HEAT! Switch on side of furnace  Most furnaces will have an ON/OFF wall switch next to them Fuses and/or circuit breaker  Make sure fu

Página 78

 Protection of compressor to reduce excessive cycling  Remote sensors sense temperature in different spaces  Outside  Inside  Sensors serve as c

Página 79 - Switch on side of furnace

• There is NO HEAT! Thermostat settings  Is thermostat in HEAT mode and calling for heat? Wiring  Is thermostat wired properly and is jumper there?

Página 80 - • There is NO HEAT!

• Overview Catalog in Spanish…150-2284 • Thermostat Catalog in Spanish…150-2208

Página 81

• Order Sell Sheets 150-2317 and 150-2318

Página 82

• Order Sell Sheets: 150-2089, 150-2090 and 150-2091

Página 83

• Order Sell Sheets: 150-2080 & 150-2082

Página 84

What is activated when UP and DOWN buttons are pushed simultaneously for 10 seconds? a) Password Setup b) System Test Mode c) Pop-Up Menu d) Auto chan

Página 85

Robertshaw® RS456 Series Wall Thermostats are powered by: a) 24 Volts AC and/or AA Batteries b) Line Voltage and/or AAA Batteries c) Line Voltage only

Página 86

I2 SERIES WALL THERMOSTAT

Página 87 - I2 SERIES WALL THERMOSTAT

 Setup Wizard  Language  Time and Date  Time Format (12 or 24 hours)  Auto Adjust Daylight Savings Time  Temperature Scales (°C or °F)  Set Sch

Página 88 -  Fan Settings

System Settings  Equipment Setup  Residual cooling  Balance points  Limits  Auto changeover  Contacts  User Security (code is 4199)  System se

Página 89 -  Contacts

 Time of Day Zoning allows user to prioritize the temperature in a room during a selected event  Depends on Rooms:  Upstairs vs. Downstairs  Basem

Página 90 -  Set Relative Humidity %

 Humidity (9800 series only)  Dehumidity (9800 series only)  Set Relative Humidity %

Página 91 -  2nd Stage Heat Equipment

 1st Stage Heat Equipment  None, Furnace, Strip or Heat pump  2nd Stage Heat Equipment  None, Furnace, Strip or Heat pump  Enable Auto Changeover

Página 92

Exercise 1  12 hour, F, 1 Heat/1 Cool, Strip heat  Fan ON continuous Exercise 2  24 hour, C, 2 Heat/ 2 Cool, Heat Pump, Furnace  Fan ON 10 min, F

Página 93 - 9725i2 same except

9801i2 Wiring 9825i2 Wiring 9725i2 same except 9701i2 same except

Página 94

– C: 24 VAC Common – R: 24 VAC – Y1: 1st stage cooling – E/W1: Emergency heat / 1st stage heating – W2: 2nd stage heating – Y2: 2nd stage cooling – L:

Página 95 - Websites:

Telephones: Technical Service 1-800-445-8299 Technical Service Fax 1-630-260-7294 Customer Service 1-800-304-6563 Customer Servi